FreeBSD* Driver for Intel(R) Ethernet

================================================================================

published date

================================================================================

Contents
--------

- Overview
- Identifying Your Adapter
- Building and Installation
- Speed and Duplex Configuration
- Additional Configurations
- Known Limitations
- Support
- License


================================================================================


Overview
--------
This file describes the FreeBSD* driver for Intel(R) Ethernet. This driver has
been developed for use with all community-supported versions of FreeBSD.

For questions related to hardware requirements, refer to the documentation
supplied with your Intel Ethernet Adapter. All hardware requirements listed
apply to use with FreeBSD.


Identifying Your Adapter
------------------------
This release includes two gigabit FreeBSD base Drivers for Intel(R)
Ethernet. These drivers are em and igb.

- The igb driver supports all 82575 and 82576-based gigabit network connections.
- The em driver supports all other gigabit network connections.

NOTE: The Intel(R) 82562v 10/100 Network Connection only provides 10/100
support.

For information on how to identify your adapter, go to the Adapter &
Driver ID Guide at:
http://support.intel.com/support/go/network/adapter/proidguide.htm

For the latest Intel network drivers, refer to the
following website and select your adapter.
http://www.intel.com/support


================================================================================


Building and Installation
-------------------------

NOTE: This driver package is to be used only as a standalone archive and the
user should not attempt to incorporate it into the kernel source tree.
In the instructions below, x.x.x is the driver version as indicated in the name
of the driver tar file.

1. Move the base driver tar file to the directory of your choice. For
   example, use /home/username/em or /usr/local/src/em.

2. Untar/unzip the archive:

   tar xzf em-x.x.x.tar.gz

This will create the em-x.x.x directory.

3. To install man page:

   cd em-x.x.x
   gzip -c em.4 > /usr/share/man/man4/em.4.gz

4. To load the driver onto a running system:

   cd em-x.x.x/src
   make load

5. To assign an IP address to the interface, enter the following:

   ifconfig em<interface_num> <IP_address>

6. Verify that the interface works. Enter the following, where <IP_address>
   is the IP address for another machine on the same subnet as the interface
   that is being tested:

   ping <IP_address>

7. If you want the driver to load automatically when the system is booted:

   cd em-x.x.x/src
   make
   make install

Edit /boot/loader.conf, and add the following line:
   if_em_load="YES"

Edit /etc/rc.conf, and create the appropriate ifconfig_em<interface_num> entry:

   ifconfig_em<interface_num>="<ifconfig_settings>"

Example usage:
   ifconfig_em0="inet 192.168.10.1 netmask 255.255.255.0"

    NOTE: For assistance, see the ifconfig man page.


================================================================================


Speed and Duplex Configuration
------------------------------

In addressing speed and duplex configuration issues, you need to
distinguish between copper-based adapters and fiber-based adapters.

In the default mode, an Intel(R) Network Adapter using copper connections
will attempt to auto-negotiate with its link partner to determine the best
setting. If the adapter cannot establish link with the link partner using
auto-negotiation, you may need to manually configure the adapter and link
partner to identical settings to establish link and pass packets. This
should only be needed when attempting to link with an older switch that
does not support auto-negotiation or one that has been forced to a specific
speed or duplex mode. Your link partner must match the setting you choose.

Caution: Only experienced network administrators should force speed and
duplex manually. The settings at the switch must always match the adapter
settings. Adapter performance may suffer or your adapter may not
operate if you configure the adapter differently from your switch.

An Intel(R) Network Adapter using fiber-based connections, however, will not
attempt to auto-negotiate with its link partner since those adapters operate
only in full duplex and only at their native speed.

By default, the adapter auto-negotiates the speed and duplex of the
connection. If there is a specific need, the ifconfig utility can be
used to configure the speed and duplex settings on the adapter.

NOTE: For the Intel(R) Ethernet Connection X552 10 GbE SFP+ you must specify
the desired speed. 

Example usage:
   ifconfig emX <IP_address> media 100baseTX mediaopt full-duplex

NOTE: Only use mediaopt to set the driver to full-duplex. If mediaopt is
not specified and you are not running at gigabit speed, the driver
defaults to half-duplex.

If the interface is currently forced to 100 full duplex, you must use this
command to change to half duplex:

ifconfig emX <IP_address> media 100baseTX -mediaopt full-duplex
This driver supports the following media type options:

Media Type		Description
----------		-----------
autoselect		Enables auto-negotiation for speed and duplex.
10baseT/UTP		Sets speed to 10 Mbps. Use the ifconfig mediaopt
			option to select full-duplex mode.
100baseTX		Sets speed to 100 Mbps. Use the ifconfig mediaopt
			option to select full-duplex mode.
1000baseTX		Sets speed to 1000 Mbps. In this case, the driver
			supports only full-duplex mode.
1000baseSX		Sets speed to 1000 Mbps. In this case, the driver
			supports only full-duplex mode.

For more information on the ifconfig utility, see the ifconfig man page.

================================================================================


Additional Features and Configurations
-------------------------------------------


Jumbo Frames
------------
Jumbo Frames support is enabled by changing the Maximum Transmission Unit
(MTU) to a value larger than the default value of 1500.

Use the ifconfig command to increase the MTU size. For example, enter the
following where <x> is the interface number:

   ifconfig eth<x> mtu 9000

To confirm an interface's MTU value, use the ifconfig command.

To confirm the MTU used between two specific devices, use:

   route get <destination_IP_address>

NOTES:
- The maximum MTU setting for Jumbo Frames is 16110. This value coincides
  with the maximum Jumbo Frames size of 16132 bytes.
- This driver will attempt to use multiple page sized buffers to receive
  each jumbo packet. This should help to avoid buffer starvation issues
  when allocating receive packets.
- Using Jumbo frames at 10 or 100 Mbps is not supported and may result in
  poor performance or loss of link.
- Some Intel gigabit adapters that support Jumbo Frames have a frame size
  limit of 9238 bytes, with a corresponding MTU size limit of 9216 bytes.
  The adapters with this limitation are based on the Intel(R) 82571EB,
  82572EI, 82573L, 82566, 82562, and 80003ES2LAN controller. These
  correspond to the following product names:
   Intel(R) PRO/1000 PT Server Adapter
   Intel(R) PRO/1000 PT Desktop Adapter
   Intel(R) PRO/1000 PT Network Connection
   Intel(R) PRO/1000 PT Dual Port Server Adapter
   Intel(R) PRO/1000 PT Dual Port Network Connection
   Intel(R) PRO/1000 PT Quad Port Server Adapter
   Intel(R) PRO/1000 PF Quad Port Server Adapter
   Intel(R) PRO/1000 PF Server Adapter
   Intel(R) PRO/1000 PF Network Connection
   Intel(R) PRO/1000 PF Dual Port Server Adapter
   Intel(R) PRO/1000 PB Server Connection
   Intel(R) PRO/1000 PL Network Connection
   Intel(R) PRO/1000 EB Network Connection with I/O Acceleration
   Intel(R) PRO/1000 EB Backplane Connection with I/O Acceleration
   Intel(R) 82566DM-2 Gigabit Network Connection
   Intel(R) 82574L Gigabit Network Connection
   Intel(R) Gigabit CT Desktop Adapter
   Intel(R) 82567LM-4 Gigabit Network Connection
   Intel(R) 82567LM-3 Gigabit Network Connection
   Intel(R) 82567LF-3 Gigabit Network Connection
- The following adapters limit Jumbo Frames sized packets to a maximum of
  4088 bytes:
  - Intel(R) 82578DM Gigabit Network Connection
  - Intel(R) 82577LM Gigabit Network Connection
- The following adapters do not support Jumbo Frames:
  - Intel(R) PRO/1000 Gigabit Server Adapter
  - Intel(R) PRO/1000 PM Network Connection
  - Intel(R) 82562G 10/100 Network Connection
  - Intel(R) 82562G-2 10/100 Network Connection
  - Intel(R) 82562GT 10/100 Network Connection
  - Intel(R) 82562GT-2 10/100 Network Connection
  - Intel(R) 82562V 10/100 Network Connection
  - Intel(R) 82562V-2 10/100 Network Connection
  - Intel(R) 82566DC Gigabit Network Connection
  - Intel(R) 82566DC-2 Gigabit Network Connection
  - Intel(R) 82566DM Gigabit Network Connection
  - Intel(R) 82566MC Gigabit Network Connection
  - Intel(R) 82566MM Gigabit Network Connection
  - Intel(R) 82567V-3 Gigabit Network Connection
  - Intel(R) 82577LC Gigabit Network Connection
  - Intel(R) 82578DC Gigabit Network Connection
- Jumbo Frames cannot be configured on an 82579-based Network device if
  MACSec is enabled on the system.


VLANS
-----
To create a new VLAN interface:

  ifconfig <vlan_name> create

To associate the VLAN interface with a physical interface and
assign a VLAN ID, IP address, and netmask:

  ifconfig <vlan_name> <ip_address> netmask <subnet_mask> vlan
    <vlan_id> vlandev <physical_interface>

Example:

  ifconfig vlan10 10.0.0.1 netmask 255.255.255.0 vlan 10 vlandev em0

In this example, all packets will be marked on egress with 802.1Q VLAN tags,
specifying a VLAN ID of 10.

To remove a VLAN interface:
  ifconfig <vlan_name> destroy


Polling
-------
NOTES:
- Device Polling is only valid for non-SMP kernels.
- The driver has to be built into the kernel for Device Polling to be
  enabled in the driver.

To enable polling in the driver, add the following options to the kernel
configuration, and then recompile the kernel:

  options DEVICE_POLLING
  options HZ=1000

At runtime use:
  ifconfig emX polling (to turn polling on)
and:
  ifconfig emX -polling (to turn it off)


Checksum Offload
----------------

Checksum offloading is not supported on 82542 Gigabit adapters.

Checksum offloading supports both TCP and UDP packets and is supported for both
transmit and receive.

Checksum offloading can be enabled or disabled using ifconfig. Both transmit and
receive offloading will be either enabled or disabled together. You cannot
enable/disable one without the other.

To enable checksum offloading:
  ifconfig emX rxcsum

To disable checksum offloading:
  ifconfig emX -rxcsum

To confirm the current setting:
  ifconfig emX

Look for the presence or absence of the following line:
  options=3 <RXCSUM,TXCSUM>

See the ifconfig man page for further information.


TSO
---
TSO (TCP Segmentation Offload) supports both IPv4 and IPv6. TSO can be 
disabled and enabled using the ifconfig utility or sysctl.

NOTE: TSO requires Tx checksum, if Tx checksum is disabled, TSO will also 
be disabled.

NOTE: By default only PCI-Express adapters are ENABLED to do TSO. Others
can be enabled by the user at their own risk. TSO is not supported on 82547 or
82544-based adapters, as well as older adapters.

To enable/disable TSO in the stack:
  sysctl net.inet.tcp.tso=0 (or 1 to enable it)

Doing this disables/enables TSO in the stack and affects all installed adapters.

To disable BOTH TSO IPv4 and IPv6:
  ifconfig em<interface_num> -tso

To enable BOTH TSO IPv4 and IPv6:
  ifconfig em<interface_num> tso

You can also enable/disable IPv4 TSO or IPv6 TSO individually. Simply replace
tso|-tso in the above command with tso4 or tso6. For example, to disable
TSO IPv4:
  ifconfig em<interface_num> -tso4


MSI-X
-----
The FreeBSD driver offers MSI-X support with 82574L-based network connections.
82574L-based network connections will use MSI-X by default.

MSI or MSI-X can be turned off by an entry in /etc/sysctl.conf

  hw.em.enable_msi=0

Unload and reload the driver.


================================================================================


Known Issues/Troubleshooting
----------------------------


Detected Tx Unit Hang in Quad Port Adapters
-------------------------------------------

In some cases ports 3 and 4 don't pass traffic and report 'Detected Tx Unit
Hang' followed by 'NETDEV WATCHDOG: ethX: transmit timed out' errors. Ports 1
and 2 do not show any errors and will pass traffic.

This issue may be resolved by updating to the latest kernel and BIOS. The user
is encouraged to run an OS that fully supports MSI interrupts. You can check
your system BIOS by downloading the Linux Firmware Developer Kit at
http://www.linuxfirmwarekit.org/.


There are known performance issues with this driver when running UDP traffic
with Jumbo Frames.
----------------------------------------------------------------------------


82541/82547 can't link or is slow to link with some link partners
-----------------------------------------------------------------

There is a known compatibility issue where time to link is slow or link is not
established between 82541/82547 controllers and some switches. Known switches
include:
  Planex FXG-08TE
  I-O Data ETG-SH8

The driver can be compiled with the following changes:

  Edit ./em.x.x.x/src/if_em.h to change the #define EM_MASTER_SLAVE

For example, change from:

  #define EM_MASTER_SLAVE  e1000_ms_hw_default

to:

  #define EM_MASTER_SLAVE  2

Use one of the following options:
  1 = Master mode
  2 = Slave mode
  3 = Auto master/slave
Setting 2 is recommended.

Recompile the module:
  a. To compile the module
	cd em-x.x.x
	make clean
	make
  b. To install the compiled module in system directory:
	make install


================================================================================


Support
-------
For general information, go to the Intel support website at:
www.intel.com/support/

or the Intel Wired Networking project hosted by Sourceforge at:
http://sourceforge.net/projects/e1000
If an issue is identified with the released source code on a supported
kernel with a supported adapter, email the specific information related to the
issue to freebsdnic@mailbox.intel.com


================================================================================


License
-------

This program is free software; you can redistribute it and/or modify it under
the terms and conditions of the GNU General Public License, version 2, as
published by the Free Software Foundation.

This program is distributed in the hope it will be useful, but WITHOUT ANY
WARRANTY; without even the implied warranty of MERCHANTABILITY or FITNESS FOR
A PARTICULAR PURPOSE. See the GNU General Public License for more details.

You should have received a copy of the GNU General Public License along with
this program; if not, write to the Free Software Foundation, Inc., 51 Franklin
St - Fifth Floor, Boston, MA 02110-1301 USA.

The full GNU General Public License is included in this distribution in the
file called "COPYING".

Copyright(c) 1999-2015 Intel Corporation.